Low-Voltage Current Transformer
308A3608。
308A3612
308A3613。
308A3623。
SAM_3624
1/2
<< /span>
>

Low-Voltage Current Transformer

●Current, electrical energy measurement or relay protection in 50Hz/60Hz A.C. circuits
●Rated voltage ≤0.5kV
●Middle open window area for let-through bus and Metal plate base for CT fixing installation
●Fully encapsulated by unsaturated resin casting.

Applications/Features:

 

●Current, electrical energy measurement or relay protection in 50Hz/60Hz A.C. circuits

●Rated voltage ≤0.5kV

●Middle open window area for let-through bus and Metal plate base for CT fixing installation

●Fully encapsulated by unsaturated resin casting.

●Comply to GB20840.1, GB20840.2, JJG1021 etc. relevant standard requirements

 

Service Conditions:

 

Installation location:

Indoor and serious vibration and earth tremors are negligible

Ambient Temperature:

-5℃~+40℃

Relative Humidity:

Less than 80%

Altitude:

Not exceeding than1000m

Atmosphere:

No obvious contaminations, such as dust, smoke, corrosive gases, vapors or salt etc

 

Technical Specification:

 

Rated Voltage:

0.5 | 0.66kV

Working frequency:

50/60Hz

Rated secondary current:

5A/1A

Polarity:

Subtractive

Rated Power Factor:

cosφ=0.8 (lagging)

Rated continuous thermal current:

1.2

Rated insulation level:

0.72/3kV

Service life:

MTTF: more than 20 years under normal operations

Terminal indication

P1、P2: Primary

S1、S2: Secondary

 

LMZ Series Low-Voltage Current Transformer

 

product-1487-625

 

Outline Dimensions:

1.LMZ(J)1-0.5 /5~400A

product-673-514

 

Model

Rated Primary Current

(A)

H

h

D

d

LMZ1-0.5

5,10,20,50,100

119

71

94

25

15,30,40,75,150,200

30

250,300

125

74

97

35

400

45

LMZJ1-0.5

5~300

35

40,200,400

45

 

2.LMZJ1-0.5 /500~800A

product-597-500

 

Model

Rated Primary Current

(A)

H

h

D

d

B

N

b

LMZJ1-0.5

500,600

130

75

106

40

46

9

53

750,800

140

80

115

50

52

12

63

 

3.LMZJ1-0.5 /1000~4000A

product-775-559

Model

Rated Primary Current(A)

A1

A2

B

h

H

L1

L2

E

C

LMZJ1-0.5

1000,1200,1500

171

98

50

91

152

152

120

37

41

2000,3000,4000

216

138

70

102

182

175

150

42

46

 

BH Series Low-Voltage Current Transformer

 

product-1485-573

 

Outline dimensions:

product-935-805

product-959-759

 

product-963-363

Model

Rated Current Ratio

Rated Secondary Burden(VA)

Primary Turns

Note

1

class

0.5

Class

0.5S

Class

0.2

Class

0.2S Class

BH-0.66

LMK-0.66

5/5-75/5

5

2.5

/

/

/

/

Figure 1

5/1-75/1

5

2.5

/

/

/

/

BH-0.66 20

75/5-100/5

2.5

/

/

/

/

1

 

75/1-100/1

2.5

/

/

/

/

1

Figure 2

BH-0.66 30

LMZ-0.66/30

30∕5

5

2.5

/

/

/

5

Figure 3

50∕5

5

2.5

/

/

/

3

75∕5

5

2.5

/

/

/

2

75∕5

2.5

/

/

/

/

1

100∕5

2.5

/

/

/

/

1

100∕5

5

5

/

/

/

2

150∕5

5

2.5

/

/

/

1

200∕5-400∕5

5

5

/

/

/

1

30/1

0.5

2.5

/

/

/

5

50/1

0.5

2.5

/

/

/

3

75/1

2.5

1

/

/

/

1

75/1

5

2.5

/

/

/

2

100/1

2.5

/

/

/

/

1

100/1

5

5

/

/

/

2

150/1

5

2.5

/

/

/

1

200/1-300/1

5

5

/

/

/

1

BH-0.66 30B

LMZ-0.66/30 B

30∕5

/

/

2.5

2.5

/

5

Figure 4

50∕5

/

/

2.5

2.5

/

3

75∕5

/

/

2.5

2.5

/

2

75∕5

5

5

/

/

/

1

100∕5

2.5

2.5

/

/

/

1

100∕5

/

/

5

5

5

2

150∕5

/

/

2.5

2.5

2.5

1

200∕5-300∕5

/

/

5

5

5

1

30/1

2.5

/

/

/

/

5

50/1

2.5

/

/

/

/

3

75/1-100/1

5

2.5

/

/

/

2

150/1

5

2.5

/

/

/

1

200/1-250/1

5

5

/

2.5

/

1

BH-0.66 40

LMZ-0.66/40

30∕5

5

2.5

/

/

/

5

Figure 5

50∕5

5

2.5

/

/

/

3

75∕5

5

2.5

/

/

/

2

75∕5-100∕5

2.5

/

/

/

/

1

100∕5

5

5

/

/

/

2

150∕5

5

2.5

/

/

/

1

200∕5-400∕5

5

5

/

/

/

1

500∕5-600∕5

10

10

5

5

5

1

30/1

5

2.5

/

/

/

2

50/1-75/1

5

2.5

/

/

/

1

100/1-150/1

5

2.5

/

/

/

1

200/1-400/1

5

5

/

/

/

1

500/1

10

10

/

5

/

1

BH-0.66 50

LMZ-0.66/50

150∕5

2.5

/

/

/

/

1

Figure 6

200∕5

5

2.5

/

/

/

1

250∕5-400∕5

5

5

/

/

/

1

500∕5-600/5

10

10

5

5

5

1

750∕5-1000∕5

10

10

10

10

5

1

1200∕5

20

20

20

20

5

1

150/1

2.5

/

/

/

/

1

200/1-400/1

5

5

/

/

/

1

500/1-600/1

10

10

/

5

/

1

750/1-1000/1

10

10

/

10

/

1

BH-0.66 60LMZ-0.66/60

200∕5

5

/

/

/

/

1

Figure 7

250∕5-400∕5

5

5

/

/

/

1

500∕5-600∕5

10

10

5

5

5

1

750∕5-1000∕5

10

10

10

10

5

1

1200∕5

20

20

20

20

5

1

1500/5

20

20

20

20

10

1

200/1

5

/

/

/

/

1

250/1-400/1

5

5

/

/

/

1

500/1-600/1

10

10

/

5

/

1

750/1-1000/1

10

10

/

10

/

1

1200/1

20

20

/

20

/

1

BH-0.66 80

LMZ-0.66/80

300∕5-400∕5

5

5

/

/

/

1

Figure 8

500∕5-600∕5

10

10

/

/

/

1

750∕5-1000∕5

10

10

10

10

5

1

1200∕5

20

20

20

20

5

1

1500∕5-2000∕5

20

20

20

20

10

1

300/1-400/1

5

5

/

/

/

1

500/1-600/1

10

10

/

/

/

1

750/1-1000/1

10

10

/

10

/

1

1200/1-1500/1

20

20

/

20

/

1

BH-0.66 100LMZ-0.66/1000

600∕5

10

10

/

/

/

1

Figure 9

750∕5-1000∕5

10

10

10

10

5

1

1200∕5

20

20

20

20

5

1

1200∕5-2000∕5

20

20

20

20

10

1

2500∕5

40

40

40

40

10

1

600/1-1000/1

10

10

/

10

/

1

1200/1-2000/1

20

20

/

20

/

1

BH-0.66 120

LMZ-0.66/120

1000∕5

10

10

10

10

5

1

Figure 10

1200/5

20

20

20

20

5

1

1500∕5-2000∕5

20

20

20

20

10

1

2500∕5-4000∕5

40

40

40

40

10

1

1000/1

10

10

/

10

/

1

1200/1-2000/1

20

20

/

20

/

1

2500/1-3000/1

40

40

/

40

/

1

 

LQG Series Low-Voltage Current Transformer

 

Applications/Features:

Current, electrical energy measurement or relay protection in 50Hz/60Hz AC circuit

Rated voltage: 0.66kV or below

With plastic casing and full encapsulation

Comply to GB20840.1, GB20840.2 and JJG1021 etc. standard requirements

 

Service Conditions:

Installation location:

Indoor and serious vibration and earth tremors are negligible

Ambient Temperature:

-5℃~+40℃

Relative Humidity:

Less than 80%

Altitude:

Not exceeding than1000m

Atmosphere:

No obvious contaminations, such as dust, smoke, corrosive gases, vapors or salt etc

 

Technical Specification:

Rated Voltage:

0.66kV

Working frequency:

50Hz

Rated secondary current:

5A

Rated continuous thermal current:

1.2

1 Second Thermal current (r.m.s) (kA)

50Ipr

Dynamic stable current (Peak value) (kA)

100Ipr

Polarity:

Subtractive

Rated Power Factor:

cosφ=0.8 (lagging)

Rated insulation level:

0.72/3kV

Service life:

MTTF: more than 20 years under normal operations

Terminal indication

P1、P2: Primary

S1、S2: Secondary

 

Model

Rated Current Ratio(A)

Rated Burden

0.5

0.5S

0.2

LQG-0.66A

5/5-400/5

10

10

5

500/5-1500/5

10

10

10

LQG-0.66B

5/5-1500/5

10

10

10

 

Outline dimensions:

1.LQG-0.66A

product-1013-658

2.LQG-0.66B

product-1015-543

 

FAQ

 

What can you buy from us?
Amorphous alloy Ribbon/Strip/Amorphous Transformer Iron Cores/Magnetic Powder Cores/Nanocrystalline Ultra-thin Ribbon/Nanocyrstalline cores /silicon steel cores/Common-mode Inductor/reactores/metering parts(included all kinds of current transformers), etc.

 

What services can we provide?
Almost all products can be customized according to customer’s needs, please ask clearly with our Customer Service.

 

For additional information and immediate assistance with your requirements, designs and applications, please call 021-63306968 Or send email to :sales@sunbowgroup.com

 

our workshop

 

our workshop

 

our equipment

 

our equipment1

our equipment2

 

our testing

 

our testing1

our testing2

 

our certification

 

our certification

 

our production process

 

our production process

 

our exhibition

 

page-1200-1200

 

Hot Tags: low-voltage current transformer, China low-voltage current transformer manufacturers, suppliers, factory, Split core Current Transformer, closed loop current sensor, Current Transformer, Low Voltage Current Transformer, toroid current transformer, Current Transformer for Current Monitoring

Send Inquiry

(0/10)

clearall