●Current, electrical energy measurement or relay protection in 50Hz/60Hz A.C. circuits
●Rated voltage ≤0.5kV
●Middle open window area for let-through bus and Metal plate base for CT fixing installation
●Fully encapsulated by unsaturated resin casting.
Applications/Features:
●Current, electrical energy measurement or relay protection in 50Hz/60Hz A.C. circuits
●Rated voltage ≤0.5kV
●Middle open window area for let-through bus and Metal plate base for CT fixing installation
●Fully encapsulated by unsaturated resin casting.
●Comply to GB20840.1, GB20840.2, JJG1021 etc. relevant standard requirements
Service Conditions:
|
Installation location: |
Indoor and serious vibration and earth tremors are negligible |
|
Ambient Temperature: |
-5℃~+40℃ |
|
Relative Humidity: |
Less than 80% |
|
Altitude: |
Not exceeding than1000m |
|
Atmosphere: |
No obvious contaminations, such as dust, smoke, corrosive gases, vapors or salt etc |
Technical Specification:
|
Rated Voltage: |
0.5 | 0.66kV |
|
Working frequency: |
50/60Hz |
|
Rated secondary current: |
5A/1A |
|
Polarity: |
Subtractive |
|
Rated Power Factor: |
cosφ=0.8 (lagging) |
|
Rated continuous thermal current: |
1.2 |
|
Rated insulation level: |
0.72/3kV |
|
Service life: |
MTTF: more than 20 years under normal operations |
|
Terminal indication |
P1、P2: Primary S1、S2: Secondary |
LMZ Series Low-Voltage Current Transformer

Outline Dimensions:
1.LMZ(J)1-0.5 /5~400A

|
Model |
Rated Primary Current (A) |
H |
h |
D |
d |
|
LMZ1-0.5 |
5,10,20,50,100 |
119 |
71 |
94 |
25 |
|
15,30,40,75,150,200 |
30 |
||||
|
250,300 |
125 |
74 |
97 |
35 |
|
|
400 |
45 |
||||
|
LMZJ1-0.5 |
5~300 |
35 |
|||
|
40,200,400 |
45 |
2.LMZJ1-0.5 /500~800A

|
Model |
Rated Primary Current (A) |
H |
h |
D |
d |
B |
N |
b |
|
LMZJ1-0.5 |
500,600 |
130 |
75 |
106 |
40 |
46 |
9 |
53 |
|
750,800 |
140 |
80 |
115 |
50 |
52 |
12 |
63 |
3.LMZJ1-0.5 /1000~4000A

|
Model |
Rated Primary Current(A) |
A1 |
A2 |
B |
h |
H |
L1 |
L2 |
E |
C |
|
LMZJ1-0.5 |
1000,1200,1500 |
171 |
98 |
50 |
91 |
152 |
152 |
120 |
37 |
41 |
|
2000,3000,4000 |
216 |
138 |
70 |
102 |
182 |
175 |
150 |
42 |
46 |
BH Series Low-Voltage Current Transformer

Outline dimensions:



|
Model |
Rated Current Ratio |
Rated Secondary Burden(VA) |
Primary Turns |
Note |
||||
|
1 class |
0.5 Class |
0.5S Class |
0.2 Class |
0.2S Class |
||||
|
BH-0.66Ⅰ LMK-0.66 |
5/5-75/5 |
5 |
2.5 |
/ |
/ |
/ |
/ |
Figure 1 |
|
5/1-75/1 |
5 |
2.5 |
/ |
/ |
/ |
/ |
||
|
BH-0.66 20Ⅰ |
75/5-100/5 |
2.5 |
/ |
/ |
/ |
/ |
1 |
|
|
75/1-100/1 |
2.5 |
/ |
/ |
/ |
/ |
1 |
Figure 2 |
|
|
BH-0.66 30Ⅰ LMZ-0.66/30 |
30∕5 |
5 |
2.5 |
/ |
/ |
/ |
5 |
Figure 3 |
|
50∕5 |
5 |
2.5 |
/ |
/ |
/ |
3 |
||
|
75∕5 |
5 |
2.5 |
/ |
/ |
/ |
2 |
||
|
75∕5 |
2.5 |
/ |
/ |
/ |
/ |
1 |
||
|
100∕5 |
2.5 |
/ |
/ |
/ |
/ |
1 |
||
|
100∕5 |
5 |
5 |
/ |
/ |
/ |
2 |
||
|
150∕5 |
5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
200∕5-400∕5 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
30/1 |
0.5 |
2.5 |
/ |
/ |
/ |
5 |
||
|
50/1 |
0.5 |
2.5 |
/ |
/ |
/ |
3 |
||
|
75/1 |
2.5 |
1 |
/ |
/ |
/ |
1 |
||
|
75/1 |
5 |
2.5 |
/ |
/ |
/ |
2 |
||
|
100/1 |
2.5 |
/ |
/ |
/ |
/ |
1 |
||
|
100/1 |
5 |
5 |
/ |
/ |
/ |
2 |
||
|
150/1 |
5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
200/1-300/1 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
BH-0.66 30ⅠB LMZ-0.66/30 B |
30∕5 |
/ |
/ |
2.5 |
2.5 |
/ |
5 |
Figure 4 |
|
50∕5 |
/ |
/ |
2.5 |
2.5 |
/ |
3 |
||
|
75∕5 |
/ |
/ |
2.5 |
2.5 |
/ |
2 |
||
|
75∕5 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
100∕5 |
2.5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
100∕5 |
/ |
/ |
5 |
5 |
5 |
2 |
||
|
150∕5 |
/ |
/ |
2.5 |
2.5 |
2.5 |
1 |
||
|
200∕5-300∕5 |
/ |
/ |
5 |
5 |
5 |
1 |
||
|
30/1 |
2.5 |
/ |
/ |
/ |
/ |
5 |
||
|
50/1 |
2.5 |
/ |
/ |
/ |
/ |
3 |
||
|
75/1-100/1 |
5 |
2.5 |
/ |
/ |
/ |
2 |
||
|
150/1 |
5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
200/1-250/1 |
5 |
5 |
/ |
2.5 |
/ |
1 |
||
|
BH-0.66 40Ⅰ LMZ-0.66/40 |
30∕5 |
5 |
2.5 |
/ |
/ |
/ |
5 |
Figure 5 |
|
50∕5 |
5 |
2.5 |
/ |
/ |
/ |
3 |
||
|
75∕5 |
5 |
2.5 |
/ |
/ |
/ |
2 |
||
|
75∕5-100∕5 |
2.5 |
/ |
/ |
/ |
/ |
1 |
||
|
100∕5 |
5 |
5 |
/ |
/ |
/ |
2 |
||
|
150∕5 |
5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
200∕5-400∕5 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
500∕5-600∕5 |
10 |
10 |
5 |
5 |
5 |
1 |
||
|
30/1 |
5 |
2.5 |
/ |
/ |
/ |
2 |
||
|
50/1-75/1 |
5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
100/1-150/1 |
5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
200/1-400/1 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
500/1 |
10 |
10 |
/ |
5 |
/ |
1 |
||
|
BH-0.66 50Ⅰ LMZ-0.66/50 |
150∕5 |
2.5 |
/ |
/ |
/ |
/ |
1 |
Figure 6 |
|
200∕5 |
5 |
2.5 |
/ |
/ |
/ |
1 |
||
|
250∕5-400∕5 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
500∕5-600/5 |
10 |
10 |
5 |
5 |
5 |
1 |
||
|
750∕5-1000∕5 |
10 |
10 |
10 |
10 |
5 |
1 |
||
|
1200∕5 |
20 |
20 |
20 |
20 |
5 |
1 |
||
|
150/1 |
2.5 |
/ |
/ |
/ |
/ |
1 |
||
|
200/1-400/1 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
500/1-600/1 |
10 |
10 |
/ |
5 |
/ |
1 |
||
|
750/1-1000/1 |
10 |
10 |
/ |
10 |
/ |
1 |
||
|
BH-0.66 60ⅠLMZ-0.66/60 |
200∕5 |
5 |
/ |
/ |
/ |
/ |
1 |
Figure 7 |
|
250∕5-400∕5 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
500∕5-600∕5 |
10 |
10 |
5 |
5 |
5 |
1 |
||
|
750∕5-1000∕5 |
10 |
10 |
10 |
10 |
5 |
1 |
||
|
1200∕5 |
20 |
20 |
20 |
20 |
5 |
1 |
||
|
1500/5 |
20 |
20 |
20 |
20 |
10 |
1 |
||
|
200/1 |
5 |
/ |
/ |
/ |
/ |
1 |
||
|
250/1-400/1 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
500/1-600/1 |
10 |
10 |
/ |
5 |
/ |
1 |
||
|
750/1-1000/1 |
10 |
10 |
/ |
10 |
/ |
1 |
||
|
1200/1 |
20 |
20 |
/ |
20 |
/ |
1 |
||
|
BH-0.66 80Ⅰ LMZ-0.66/80 |
300∕5-400∕5 |
5 |
5 |
/ |
/ |
/ |
1 |
Figure 8 |
|
500∕5-600∕5 |
10 |
10 |
/ |
/ |
/ |
1 |
||
|
750∕5-1000∕5 |
10 |
10 |
10 |
10 |
5 |
1 |
||
|
1200∕5 |
20 |
20 |
20 |
20 |
5 |
1 |
||
|
1500∕5-2000∕5 |
20 |
20 |
20 |
20 |
10 |
1 |
||
|
300/1-400/1 |
5 |
5 |
/ |
/ |
/ |
1 |
||
|
500/1-600/1 |
10 |
10 |
/ |
/ |
/ |
1 |
||
|
750/1-1000/1 |
10 |
10 |
/ |
10 |
/ |
1 |
||
|
1200/1-1500/1 |
20 |
20 |
/ |
20 |
/ |
1 |
||
|
BH-0.66 100ⅠLMZ-0.66/1000 |
600∕5 |
10 |
10 |
/ |
/ |
/ |
1 |
Figure 9 |
|
750∕5-1000∕5 |
10 |
10 |
10 |
10 |
5 |
1 |
||
|
1200∕5 |
20 |
20 |
20 |
20 |
5 |
1 |
||
|
1200∕5-2000∕5 |
20 |
20 |
20 |
20 |
10 |
1 |
||
|
2500∕5 |
40 |
40 |
40 |
40 |
10 |
1 |
||
|
600/1-1000/1 |
10 |
10 |
/ |
10 |
/ |
1 |
||
|
1200/1-2000/1 |
20 |
20 |
/ |
20 |
/ |
1 |
||
|
BH-0.66 120Ⅰ LMZ-0.66/120 |
1000∕5 |
10 |
10 |
10 |
10 |
5 |
1 |
Figure 10 |
|
1200/5 |
20 |
20 |
20 |
20 |
5 |
1 |
||
|
1500∕5-2000∕5 |
20 |
20 |
20 |
20 |
10 |
1 |
||
|
2500∕5-4000∕5 |
40 |
40 |
40 |
40 |
10 |
1 |
||
|
1000/1 |
10 |
10 |
/ |
10 |
/ |
1 |
||
|
1200/1-2000/1 |
20 |
20 |
/ |
20 |
/ |
1 |
||
|
2500/1-3000/1 |
40 |
40 |
/ |
40 |
/ |
1 |
||
LQG Series Low-Voltage Current Transformer
Applications/Features:
Current, electrical energy measurement or relay protection in 50Hz/60Hz AC circuit
Rated voltage: 0.66kV or below
With plastic casing and full encapsulation
Comply to GB20840.1, GB20840.2 and JJG1021 etc. standard requirements
Service Conditions:
|
Installation location: |
Indoor and serious vibration and earth tremors are negligible |
|
Ambient Temperature: |
-5℃~+40℃ |
|
Relative Humidity: |
Less than 80% |
|
Altitude: |
Not exceeding than1000m |
|
Atmosphere: |
No obvious contaminations, such as dust, smoke, corrosive gases, vapors or salt etc |
Technical Specification:
|
Rated Voltage: |
0.66kV |
|
Working frequency: |
50Hz |
|
Rated secondary current: |
5A |
|
Rated continuous thermal current: |
1.2 |
|
1 Second Thermal current (r.m.s) (kA) |
50Ipr |
|
Dynamic stable current (Peak value) (kA) |
100Ipr |
|
Polarity: |
Subtractive |
|
Rated Power Factor: |
cosφ=0.8 (lagging) |
|
Rated insulation level: |
0.72/3kV |
|
Service life: |
MTTF: more than 20 years under normal operations |
|
Terminal indication |
P1、P2: Primary S1、S2: Secondary |
|
Model |
Rated Current Ratio(A) |
Rated Burden |
||
|
0.5 |
0.5S |
0.2 |
||
|
LQG-0.66A |
5/5-400/5 |
10 |
10 |
5 |
|
500/5-1500/5 |
10 |
10 |
10 |
|
|
LQG-0.66B |
5/5-1500/5 |
10 |
10 |
10 |
Outline dimensions:
1.LQG-0.66A

2.LQG-0.66B

FAQ
What can you buy from us?
Amorphous alloy Ribbon/Strip/Amorphous Transformer Iron Cores/Magnetic Powder Cores/Nanocrystalline Ultra-thin Ribbon/Nanocyrstalline cores /silicon steel cores/Common-mode Inductor/reactores/metering parts(included all kinds of current transformers), etc.
What services can we provide?
Almost all products can be customized according to customer’s needs, please ask clearly with our Customer Service.
For additional information and immediate assistance with your requirements, designs and applications, please call 021-63306968 Or send email to :sales@sunbowgroup.com
our workshop

our equipment


our testing


our certification

our production process

our exhibition

Hot Tags: low-voltage current transformer, China low-voltage current transformer manufacturers, suppliers, factory, Split core Current Transformer, closed loop current sensor, Current Transformer, Low Voltage Current Transformer, toroid current transformer, Current Transformer for Current Monitoring
Send Inquiry